Lab HQ: +255 758 381 273 Direct: +255 784 894 577 info@rvalabs.co.tz
WhatsApp Lab Desk Mwanza Main Lab • Regional Drop-Offs
ICP-MS-65 Multi-Element & Geochemical Analysis

ICP-MS Ultra-Trace Exploration Package (51–65 Elements)

Ultra-sensitive multi-element package detecting trace and ultra-trace pathfinder elements at parts-per-billion (ppb) levels for greenfield exploration, deep-cover targeting, and geochemical halo vectoring.

Detection Limits 0.01 ppb (0.00001 ppm) – 500 ppm
Turnaround (TAT) Standard: 5-7 Working Days
Sample Requirement 0.25g to 0.5g pulverized pulp
Quality Framework ISO/IEC 17025 Compliant

Analytical Overview & Methodology

For advanced mineral exploration beneath thick post-mineral cover and saprolite, standard detection limits are insufficient. RVA Laboratories’ ICP-MS Ultra-Trace Package (ICP-MS-65) provides mass-spectrometric sensitivity down to parts-per-trillion (ppt) and parts-per-billion (ppb) levels.

Mass Resolution & Cleanroom Environment

Prepared in specialized temperature-controlled digestion blocks with ultrapure sub-boiled acids, samples are analyzed on quadrupole ICP-MS instruments equipped with helium collision cells. This completely eliminates polyatomic argon interferences, unlocking crystalline precision for critical battery metals, lithium-cesium pegmatites, and rare earth deposits.

Technical Method Specifications (ICP-MS-65)
Method Code ICP-MS-65
Element Coverage Up to 65 Elements including REEs (Rare Earth Elements), precious pathfinders, and ultra-trace volatiles
Detection Range 0.01 ppb (0.00001 ppm) – 500 ppm
Sample Requirement 0.25g to 0.5g pulverized pulp
Instrumentation High-Resolution Quadrupole Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
Standard Turnaround Standard: 5-7 Working Days

Laboratory Protocols & Execution Specs

  • Elements Reported: 51 to 65 elements (including all 15 Rare Earth Elements)
  • Sensitivity: Parts-per-billion (ppb) and sub-ppb detection limits
  • Digestion: Ultra-pure four-acid or aqua regia in cleanroom digestion suites
  • Key Pathfinders: As, Sb, Bi, Te, Se, Tl, In, Ge, Re, U, Th, Li, Cs, Ta, Nb
  • Applications: Deep cover exploration, greenfield anomaly discovery, REE mineral exploration

JORC & NI 43-101 Data Integrity Guarantee

Every batch tested under method ICP-MS-65 includes matrix-matched Certified Reference Materials (CRMs), analytical blanks, and duplicate splits at a minimum 20% insertion rate. Official digital Certificates of Analysis are digitally signed and traceable.